Hi-Pot Tester series |
|
DU-3282 |
Multi channel Real-time Open Check Hi-Pot Tester |
|
DU-3200 |
Programmable Hi-Pot Tester |
|
DU-3280 |
Multi channel Hi-Pot Tester |
|
DU-3101 |
Hi-Pot Tester |
|
DU-3111 |
Real-time Open Check Hi-Pot Tester |
|
DU-3900 |
High Voltage Meter |
|
Transformer Test System |
|
DU-7121 |
20 channel High-speed Transformer Test System |
|
DU-7131 |
80 channel High-speed Transformer Test System |
|
DU-7151 |
96 channel High-speed Transformer Test System |
|
LCR Meter series |
|
DU-6131 |
10KHzLCR Meter |
|
DU-6132 |
100KHz LCR Meter |
|
DU-6135 |
200KHz LCR Meter |
|
DU-6136 |
200KHz LCR Meter (Programmable)
|
|
Low-Ohm Meter series |
|
DU-5130 |
DCR 0.01mΩ ~200KΩ |
|
DU-5131 |
DCR 0.001mΩ ~2MΩ |
|
DU-5132 |
DCR 0.001mΩ ~2MΩ 14ms |
|
Capacitance testing series |
|
DU-2156 |
500V19mA |
|
DU-2157 |
650V19mA |
|
DU-9001 |
Electrolytic capacitor test & scanningsystem with leakage current test |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Feature |
HI-port test |
AC: |
Test voltage: 0.10~5.00kV
Detecting current: 0.10mA ~ 12.00mA
Output frequency: 50/60HZ |
Voltage Accuracy: ±1% +5 digits
Cutoff Current:±1.5% +5 digits |
|
DC: |
Test voltage: 0.10~6.00kV
Detecting current: 0.10mA ~ 5.00mA |
Voltage Accuracy: ±1% +5 digits
Cutoff Current: ±1.5% +5 digits
|
ARC tese |
ARC: |
AC
Detecting current: 0.50mA ~ 12.00mA |
DC:
Detecting current : 0.50mA ~ 5.00mA
|
IR test |
IR:
|
Test voltage: DC: 1.00 ~ 1,00kV
Test scope: 10 MΩ~ 9,999MΩ
|
Voltage Accuracy: ±1% +5 digits
¡Ù500V : 10¡ã1000MΩ ±5%
¡Ù500V : 1001¡ã9999MΩ ±15%
< 500V : 1¡ã 200MΩ ±10%
< 500V : 201¡ã1000MΩ ±15%
|
|
3 in 1 tester with AC, DC, IR functions
ARC Detction:
DU3315 /DU3316 Standard function
40 x 4 LCD text display
Fast cut-off time : 0.4ms
5 sets of memory, 3 steps for each memory |
Specifications |
Model |
DU-3101 |
DU-3102 |
DU-3113 |
DU-3114 |
Main function |
AC |
AC/IR |
AC/DC |
AC/DC/IR |
Withstanding Volta |
Output Voltage |
AC: 0.10~5.00kV / DC: 0.10~6.00kV |
Load Regulation |
1% + 5V |
Voltage Resolution |
10V |
Voltage Accuracy |
1.5% + 5V |
Cutoff Current |
AC: 0.10mA ~ 12.00mA DC:0.10mA ~ 5.00mA |
Current Resolution |
0.01mA ~ 12.00(5.00) mA / 10µA |
Current Accuracy |
1.5% + 5counts |
Output Frequency |
50Hz / 60Hz |
Test Time |
0.3 ~ 999.9 sec , continue |
Ramp up Time |
0.1 ~ 999.9 sec , off |
Wave Form |
Sine wave |
PASS/FAIL Judgement |
Comparator Mode |
Window comparator system |
Indication |
Display PASS/FAIL and Alarm |
ARC Detection |
Setting Mode |
Programmable setting |
Detection Current |
AC: 1.0mA ~ 12.0mA , DC: 1.0mA ~ 5.0mA |
Insulation Resist |
Output Voltage |
DC: 0.10 ~ 1,00kV |
Voltage Resolution |
10V |
Voltage Accuracy |
2% + 5 V |
IR Range |
10 ~ 2,000 MΩ |
IR Accuracy |
≧5 00V : 3 % + 2 counts, < 500V : 7 % + 2 counts |
Other |
Data Hold |
Last test data memory before power off |
Step |
3 steps for each memory |
Key Lock |
Execution withstanding voltage test or insulation resistance test. |
Memory store |
5 sets |
LCD Display |
4 x 40 LCD Display |
Remote Control |
TEST / RESET remote control |
Signal Output |
PASS / FAIL / TEST with relay contact |
General |
Power Requirement |
115V/230V AC, 50/60Hz |
Accessories |
HV Test lead wires, Power Cord, Operation Manual, Certificate of Calibration |
Dimensions |
270(W) x 90(H) x 380(D) mm |
Weight |
6.7 kg |
7.2 kg |
Order Information |
DU-3101 |
Hi-Pot Tester (AC) |
DU-3102 |
Hi-Pot Tester (AC/IR) |
DU-3103 |
Hi-Pot Tester (AC/DC) |
DU-3104 |
Hi-Pot Tester (AC/DC/IR) |
Standard Fittings |
Fx33-0101 |
HV test lead wires |
Fx33-0102 |
HV test lead wires |
Optional Accessories |
Fx33-0301 |
HV test bat |
|
|
|
|
|
|
|
|
Delta United Instrument Co.,Ltd.
3F, NO. 504, Jong-Jeng Rd., Xindian Dist, New Taipei City, Taiwan.R. O.C.
Tel:886-2-86673545 Fax:886-2-86673546
sales@deltaunited.com.tw |
DONGGUAN DELTA UNITED INSTRUMENT CO., LTD.
301Rm, No. 108, Chung-Huan Middle Rd., Shijie Town, Dongguan, Guangdong, P.R.C.
Tel:86-769-86317345 Fax:86-769-86317346
sam@deltaunited.cn |
|